Analytical Instruments
Wyatt Dynapro Nanostar with Software Loaded PC
Sold out
Contact for price
BLE20000206
Key Features
- Rh from 0.18 nm - 2500 nm
- Temperature from -15°C to +150°C
- Molecular weight from 300 Da to 1 MDa
- Separate, optimized SLS and DLS detection channels
- Auto-attenuation over five orders of magnitude
- Size Range (Radius) 0.2 to 2500 nm
- Static Scattering Molecular Weight Range 300 Da to 1 MDa (sample dependent - maximum molecular radius ~ 12 nm)
- Minimum Concentration (lysozyme) *0.1 mg/mL
Optics
Laser Properties
Laser Wavelength 658 nm; 785 nm optional
Laser Power Control Programmable 10% to 100%
- Scattering Angle Detected 90°
- Sample Cell Options 1.25 µL quartz cuvette
4 µL disposable cyclic olefin copolymer (COC) cuvette
standard 1 cm cuvettes with adapter
- Temperature Range -15°C to +150°C †
Dry air or nitrogen required for operation below 20°C
- Data Acquisition Time 1 to 3600 s
Electronics
- Optical Fiber Multi-Mode
- Correlator 512 channels, multi-tau, 100 nsec sampling time
- PC ports Ethernet connectivity
Dimensions 60 cm (L) x 36 cm (W) x 18 cm (H)
Weight 13.5 kg (29.8 lbs)
Wyatt Dynapro Nanostar with Optional Software Loaded PC
Sold out
Contact for price
BLE20000162
**Software Loaded PC is Optional and available for additional cost
Key Features
- Rh from 0.18 nm - 2500 nm
- Temperature from -15°C to +150°C
- Molecular weight from 300 Da to 1 MDa
- Separate, optimized SLS and DLS detection channels
- Auto-attenuation over five orders of magnitude
- Size Range (Radius) 0.2 to 2500 nm
- Static Scattering Molecular Weight Range 300 Da to 1 MDa (sample dependent - maximum molecular radius ~ 12 nm)
- Minimum Concentration (lysozyme) *0.1 mg/mL
Optics
Laser Properties
Laser Wavelength 658 nm; 785 nm optional
Laser Power Control Programmable 10% to 100%
- Scattering Angle Detected 90°
- Sample Cell Options 1.25 µL quartz cuvette
4 µL disposable cyclic olefin copolymer (COC) cuvette
standard 1 cm cuvettes with adapter
- Temperature Range -15°C to +150°C †
Dry air or nitrogen required for operation below 20°C
- Data Acquisition Time 1 to 3600 s
Electronics
- Optical Fiber Multi-Mode
- Correlator 512 channels, multi-tau, 100 nsec sampling time
- PC ports Ethernet connectivity
Dimensions 60 cm (L) x 36 cm (W) x 18 cm (H)
Weight 13.5 kg (29.8 lbs)
Wyatt Technology Optilab rEX Model WREX-06 RI Detector
BLE2000164
Free shipping available
Major Specifications:
Differential Refractive Index Range & Sensitivity:Range (RIU) -0.0047 — + 0.0047, Peak-to-peak noise (RIU)* ± 7.5 x 10-10
High Concentration Option T-rEX: Range (RIU) -0.0026 — + 0.034, Peak-to-peak noise (RIU)* ±1.5 x 10-9
Fluid Volumes: Flow cell 7.4 μL, Inlet tubing (0.010” ID) 44 μL, Outlet tubing (0.030” ID) 370 μL
Dynamic Range: 22+ bits only via digital communication
Response Time: 0.1 - 5 seconds, user selectable
Absolute Refractive Index Range and Sensitivity: 1.2 - 1.8 RIU (sensitivity of ± 0.002 RIU)
Light Source: 660 nm standard; Other wavelengths available
Sample Temperature Control Range: 4°C - 50°C, temperature regulated
Temperature Regulation: ± 0.005°C
Maximum System Pressure: 30 psi (2 bar)
Maximum Cell Pressure: 100 psi (7 bar)
Safety Sensors: Vapor and liquid (leak)
Inputs and Outputs: Analog In 16 bit ± 10V A/D for auxiliary user data, Analog Out 18 bit D/A for dRI data, ± 10V or ± 1V output
Inputs: Zero, Purge, Recycle, Autoinject, Alarm In
Output: Autoinject Retransmit, Alarm Out, External Solenoid, Recycle Valve. 12VDC solenoid valve (sold separately, or user supplied) to switch automatically between waste and recycle
Click 'buy now' through our site to checkout with free shipping! We accept major credit cards
Rudolph Research Analytical Autopol V Plus (Part # A22502)
BLE1900005
Contact for price
- Measuring Mode: Optical Rotation, Specific Rotation, Concentration & User-defined Scales
- Measuring Scale: Degrees Arc, % Concentration
- Measuring Range: ±89.9° Arc Optical Rotation, ±999.99° Arc Specific Rotation and 0-99.9% Concentration
- Selectable Resolution: 0.01°, 0.001°, 0.0001° Arc Optical Rotation 0.001% Concentration 0.001° Specific Rotation
- Reproducibility: 0.002° Arc
- Standard Model Accuracy: 0.002° up to 1°, 0.2% up to 5°, 0.01° above 5°
- AP Model Accuracy and Resolution: (Autopol V Plus Single: ±0.002° Arc over ±89.9° Arc. Autopol V Plus Six Wavelength (546nm and 589nm): ±0.002° over ±89.9° Arc. Selectable Resolution 0.01°, 0.001°, 0.0001° Arc Optical Rotation
- Prism: Glan Thompson calcite quartz
- Optical Wavelengths: 365nm, 405nm, 436nm, 546nm, 589nm, 633nm (other wavelengths available)
- Wavelength Selection: Automatic by push-button
- TempTrol™ Range: Automatic Electronic Heating & Cooling 15°-35°C
- TempTrol™ Accuracy: ±0.2°C
- Temp. Probe Range: 10°-40°C T
- emp. Probe Accuracy: ±0.1°C
- Acid Resistance: Hastelloy™ measurement cell and Silco Steel™ sample chamber (standard)
- Measurement Time: 4°/sec. slew rate and 5 sec. nominal settling time
- Light Source: Tungsten-halogen 6V, 20W, avg. 2,000 hour life
- Sample Chamber: Accepts sample tubes up to 200mm
- Data Storage/Internal Memory: 2 GB Non-removable Compact Flash
- Communication Interface: Touch Screen, 3 – USB Ports, 2 – RS232 Ports, Ethernet Port for Network Connection, Keyboard, Bar Code Scanner, Mouse, Network Capabilities
- Calibration: Automatic calibration by push-button
- Display: 10.4 inch diagonal, 800-600 pixels, color, Flat Panel Monitor with Resistant Touch Screen Interface, 200 nits brightness, gasketted for spill protection
- User Interface: Touchscreen
- Automatic Sensitivity Control: Measures samples with transmittance as low as 0.01% (up to O.D. 4.0)
- Input Power: 85 – 260 VAC; 48 – 62 Hz, 150 – 200 Watts consumption
- Operating Dimensions: 32"W x 11.5"H x 18"D 813mm W x 292mm H x 457mm D
- Shipping Dimensions: 43"W x 28"H x 23"D 1,411mm W x 919mm H x 722mm D
- Operating Weight: 90 lbs. (41kg)
- Shipping Weight: 140 lbs. (64kg)
Rudolph Research Analytical Autopol V (Part # A20766)
BLE2000003
Contact for price
The AUTOPOL V Automatic Polarimeter is designed for today’s FDA regulated analytical laboratories. Whether you are a Pharmaceutical, Nutraceutical or University Lab, the AUTOPOL V has the standard measurement and compliance features you must have, including:
- 21CFR Part 11 Compliant
- Temptrol™ Electronic Heating and Cooling
- Six standard wavelengths
- Touch panel user interface
- Designed for use in FDA regulated Pharmaceutical, Nutraceutical and cGMP/GLP laboratories
AUTOPOL V SpecificationsMeasuring ModeOptical Rotation
Specific Rotation
Specific Rotation Plus Concentration
User Defined Scale
Sugar Degrees
°Z(ISS)
Measuring ScaleDegrees Arc, % Concentration
Measuring Range± 89.9° Arc Optical Rotation
± 999.99° Arc Specific Rotation
0-99.9% Concentration
Resolution0.001° Arc Optical Rotation
0.001% Concentration
0.001 Specific Rotation
Reproducibility0.002° Arc
Standard Model Accuracy0.002° up to 1°, 0.2% up to 5°, 0.01° above 5°
AP Model SpecsAccuracy (546nm and 589nm): ±0.002° Arc over ±89.9° Arc
Accuracy for other wavelengths is the same as the standard model
Selectable Resolution 0.01°, 0.001°, 0.0001° Arc Optical Rotation
PrismGlan Thomson calcite quartz
Optical Wavelengths365nm, 405nm, 436nm, 546nm, 589nm, 633nm
(other wavelengths available)
Wavelength SelectionTouchscreen Selectable: 6 standard
TempTrol™ RangeAutomatic Electronic Heating & Cooling 15°-35°C (Standard) ±0.2° C (Standard)
TempTrol™ Accuracy±0.2°C
Temp. Probe Range10°-100°C
Temp. Probe Accuracy±0.1°C
Acid ResistanceHastelloy™ measurement cell and Silco Steel™
sample chamber (optional)
Measurement Time4°/sec slewing rate & 5 sec nominal settling time
Light SourceTungsten-halogen 6V, 20W, avg. 2,000 hr life
Sample ChamberAccepts sample tubes up to 200mm
Data Storage32 GB Non-removable Compact Flast
Communication Interface3 - USB Ports
2 - RS232 Ports
Ethernet Port for Network Connection
CalibrationAutomatic calibration by push-button
Operating SystemWindows® Embedded
Display8 inch color LCD with LED backlight providing 800 x 600 resolution with 400 nits of luminance
User InterfaceTouchscreen
Automatic Sensitivity ControlMeasures samples with transmittance as low as 0.01 % (up to O.D. 4.0)
Input Power100-240 VAC, 50/60 Hz
Operating Dimensions30"W x 17"H x 10.5"D,
762mm W x 432mm H x 267mm D
Shipping Dimensions30"W x 11.5"H x 17"D,
762mm W x 431.8mm H x 279.4mm D
Operating Weight85 lbs (39 kg)
Shipping Weight120 lbs. (54kg)
Agilent 8453 G1103A UV-Vis Spectrophotometer
Contact for price
BLE2000234
Unit Available in the following configurations:
- Agilent 8453 G1103A Uv/Vis with PC
- Agilent 8453 G1103A Uv/Vis with Pump/switch Valve, PC
- Agilent 8453 G1103A Uv/Vis with 2 pumps/switch valve, PC (as pictured)
Wavelength range 190 - 1100 nm
Slit width 1 nm
Resolution> 1.6
Stray light < 1.0 % At 200 nm, solution of 1.2% KCl, blank scan on air, 5 s integration
time; (EP*method)**
< 0.05 % At 220 nm, solution of 10 g/l NaI, blank scan on air, 5 s integration
time; (ASTM method)
< 0.03 % At 340 nm, solution of 50 g/l NaNO2, blank scan on air, 5 s integration
time; (ASTM method
Wavelength accuracy< ± 0.5 nm
Wavelength reproducibility< ± 0.02 nm
Photometric accuracy< ± 0.005 AU
Photometric noise< 0.0002 AU rms
Photometric stability< 0.001 AU/h
Baseline flatness< 0.001 AU rms
Typical scan time1.5 s
Shortest scan time 0.1 s
Time until next scan 0.1 s
Agilent 8453 UV Vis Spectrophotometer with 8 Position Multicell Transport, Windows 10 PC, Keybaord and Mouse
Contact to purchase
BLE1900246
Includes Windows 10 PC with Chemstation B.05.04(8)
Monitor
Keyboard
Mouse
The Agilent 8453 UV-Visible Spectrophotometer G1103A uses a photodiode array (PDA) for simultaneous measurement of the complete ultra-violet to visible light spectrum in less than one second. The PDA technique brings exceptional reliability and repeatability. Using Agilent ChemStation software you get powerful data analysis and data archival to ensure compliance with good laboratory practices (GLP) and pharmacopoeia requirements. The HP 8453 spectrophotometer is a single-beam, microprocessor-controlled UV-Vis spectrophotometer with collimating optics, 190-1100nm wavelength range, 1nm slit width, ±0.5nm wavelength accuracy, less than 0.03 percent stray light, -10C to 120C temperature set range.
Features:
Fast results, UV-Vis spectral acquisition and analysis in less than 1 second
Excellent reproducibility, stable optics, low noise electronics, no moving parts
Simple operation, task-oriented and application software (not included), direct access to cells and cell holder
Effortless servicing, pre-aligned deuterium and tungsten lamps exchanged easily
Good laboratory practices (GLP), self-test and revisions built into the software (not included)/firmware
Pharmaceutical complianc regulated software for European and US pharmacopoeia
8 position 1cm sqaure cell holder.
Agilent 8453 UV Vis Spectrophotometer with 8 Position Multicell Transport, Windows 7 PC, Keybaord and Mouse
Contact to purchase
BLE1900428
Includes Windows 7 PC with Chemstation B.05.04(8)
Monitor
Keyboard
Mouse
The Agilent 8453 UV-Visible Spectrophotometer G1103A uses a photodiode array (PDA) for simultaneous measurement of the complete ultra-violet to visible light spectrum in less than one second. The PDA technique brings exceptional reliability and repeatability. Using Agilent ChemStation software you get powerful data analysis and data archival to ensure compliance with good laboratory practices (GLP) and pharmacopoeia requirements. The HP 8453 spectrophotometer is a single-beam, microprocessor-controlled UV-Vis spectrophotometer with collimating optics, 190-1100nm wavelength range, 1nm slit width, ±0.5nm wavelength accuracy, less than 0.03 percent stray light, -10C to 120C temperature set range.
Features:
Fast results, UV-Vis spectral acquisition and analysis in less than 1 second
Excellent reproducibility, stable optics, low noise electronics, no moving parts
Simple operation, task-oriented and application software (not included), direct access to cells and cell holder
Effortless servicing, pre-aligned deuterium and tungsten lamps exchanged easily
Good laboratory practices (GLP), self-test and revisions built into the software (not included)/firmware
Pharmaceutical complianc regulated software for European and US pharmacopoeia
8 position 1cm sqaure cell holder.
Agilent Technologies 8453 7 Cuvette UV Vis Spectrophotometer with Software Loaded PC, Monitor, Keyboard and Mouse
Contact to purchase
BLE1900244
System includes:
- Dell Optiplex PC loaded with Windows XP
- Installed Chemstation software v. b.01.01(21)
- Monitor
- Keyboard & Mouse
Perkin Elmer Lambda 40 UV/Vis Spectrometer
Contact for price
BLE1800032
Includes Windows 10 with UV Winlab Loaded PC
The Perkin Elmer Lambda 40 is a laboratory grade double-beam UV/Vis spectrometer. LAMBDA systems are easy to operate and deliver results you can trust with the minimum of operator training. The instrument can be operated by the front panel display or through the remote interface. Fast scan speeds, accuracy, high-resolution, low stray light, and several modes of operation are features of the Lamda 40.
- 190-1100nm Wavelength Range
- 0.1nm Wavelength Accuracy
- -3 to 3 A Photometric Range
- Stand-Alone or Computer-Controlled Operation
Wavelength Range (nm) 190 - 1100
Wavelength Accuracy (±nm) 0.1
Wavelength Repeatability (±nm) 0.05
Resolution (nm) 0.5
Max Scan Speed (nm/min) 2800
Monochrometer Single, Grating
Stray Light %T @ 340nm 0.01
Photometric Range (A) -3 to 3
Photometric Accuracy (A) ±0.003
Baseline Stability (A/hr) 0.00015
Baseline Flatness (A) ± 0.0005
Slit Widths (motorized) 0.5, 1.0, 2.0, 4.0 mm
Display Digitial, Touch Key
Source Types Halogen, D2
Dimensions: D57 x W65 x H26
Weight: 57 lbs.
Power: 110V to 240VAC, 50/60Hz
Perkin Elmer Lambda35 Uv-Visible Spectrophotometer
Contact for price
SN 502S09102209
Fully tested and ready to ship. Spectrometer is in excellent condition. 30 Day Money Back Guarantee!!!
Software Loaded PC included. UV Winlab Version 6.0.4
The Perkin-Elmer Lambda™ 25/35/45 UV/Visible Spectrophotometers increase productivity by mimicking the QA workflow to generate high-quality results the first time, every time. And that’s exactly what the user needs in a busy laboratory when the pressure’s on and it’s the user's job to keep the results flowing. LAMBDA systems are easy to operate and deliver results the user can trust with the minimum of operator training. With Perkin-Elmer's complete range of LAMBDA systems it’s easy to develop simple, robust methods and ensure they’re followed without mistakes. And, whichever LAMBDA system is choosen, the user's day-to-day UV/Vis analyses will be faster, simpler and more dependable than ever before.
UV WinLab™ software works the way the user works, guiding the user through a step-by-step process that simplifies analysis from sample entry to report generation, eliminating costly mistakes and delivering rapid results. The user can rely on Perkin-Elmer's proven technology to deliver consistently high-quality results over the lifetime of the system, and the user can confirm those results with Perkin-Elmer's extensive suite of Instrument Performance Verification (IPV) tests. For FDA-regulated industries, the Enhanced Security™ (ES) version of UV WinLab integrates seamless 21 CFR Part 11 technical compliance without slowing the user down.
- FeaturesTrue Double-Beam Operation
- Sealed and Quartz-Coated High-Throughput Optics
- Fast Scanning
- Prealigned Deuterium and Tungsten Halogen Lamps
- Technical description and specifications - Lambda 35Part # L6020064
- Wavelength Range - 190-1100nm
- Bandwidth - 0.5, 1, 2, 4 nm varuabke
- Stray Light - At 220nm (Nal) < 0.01%T
- At 340 nm (NaNO2) < 0.01%T
- At 370 nm (NaNO2) < 0.01%T
- At 200 nm (KCI) < 1%T
- Wavelength Accuracy - At D2 peak (656.1 nm) ±0.1 nm
- Wavelength reproducibility - 10 measurements at 656.1 nm ±0.05 nm
- Photometric Accuracy - At 1 A using NIST 930D filter ±0.001 A
- At 2 A using NIST 1930D filter ±0.005 A
- Potassium dichromate ±0.010A
- Photometric reproducibility - Maximum deviation of 10 measurements at 1 A < 0.001 A
- Photometric stability - Stability at 1 A, at 500 nm with 2-sec. response time < 0.00015 A/hour
- Photometric noise at 500 nm (RMS) - Noise 500 nm/0 A RMS Slit 1 nm < 0.00005 A
- Baseline flatness - Slit 1 nm ±0.001 A
- Construction Solid CNC-machined aluminum chassis for thermal and vibration stability
- Optics Double-beam, sealed, quartz-coated mirrors; lens-free system to reduce chromatic aberrations
- Monochromator Seya Namioka
- Grating Holographic, concave grating with 1053 lines per mm
- Source Deuterium and Tungsten prealigned sources with automatic switch-over
- Size (W x D x H) 650 mm (25 in.) x 560 mm (22 in.) x 233 mm (9 in.)
- Weight (approx.) 26 kg (57 lbs)
Advanced Instruments A20 Osmometer
Contact for price
BLE2000303
Sample test volume 100μL
Aspirated Sample volume 150μL
Sample capacity 20 sample carousel
Test time Less than 3 minutes
Sample throughput can process 20 samples in less than 1 hour
Unit mOsm/kg H2O
Calibration low: 0 to 2000 mOsm/kg H2O
full: 0 to 4000 mOsm/kg H2O
Resolution1 mOsm/kg H2O
Calibrated 3-point Calibrated for low range
4-point for full range
Communication Onbord printer, 10/100Mbps Ethernet, 4 USB 1.0/1.1/2.0 integrated bar code scanner
Accuracy 0 to 400 mOsm/kg H2O: mean value ≤ 2 mOsm/kg H2O from nominal value 400-4000 mOsm: mean value ≤ 0.5% from normal value
Precision (Within-run) standard deviation ≤ 2 mOsm/kg H2O between 0 and 400 mOsm; standard deviation ≤ 0.5% of value between 400 to 4000 mOsm
Drift Less than 1 mOsm/kg H2O per month
Temperature effects1 Recalibration recommended for ambient temperature change 5°C (9°F) or greater
Storage temperature -40°C to +45°C (-40°F to +113°F)
Simple Viscosity Up to 20 mPa-s(20 cP) higher viscosities may affect pipettor accuracy
Pipettor Accuracy< 1%Electrical voltage100-240 VAC (50/60 Hz)
Power consumption 375W
Dimensions (D x W x H)20.5″ x 23.6″ x 22.8″ (52 cm x 60 cm x 58 cm)
Net weight 68 lb (31 kg)
Shipping weight 133 lb (60 kg)
Advanced Instruments 2020 Osmometer
Contact to purchase
BLE1601271
Automated, multi-sample, designed to process a 20uL sample with a 90-second test time. The Model 2020 provides maximum productivity, accuracy and reliability.
• Up to 20 samples at one time
• 20 µL sample size is ideal for applications where the sample quantity is limited.
• Stat sample capability
• Multi-language operation
• On-board statistical analysis
• Results recall up to the last 200 tests
• On-board printer
• Connects easily to external barcode scanner
• Internal diagnostics
• Ergonomic, compact design
• Automated calibration
- ElectricalPower Requirement: 100 to 240 VAC (50-60 Hz)
- Fuses (2): 250V time delay (Type T): 2-Amp
- Power Consumption: 80 Watts
- Memory Backup: Integral lithium cell; 10-year life (typical); (not user-replaceable)
- Sample Volume: 20 μL
- Sample Capacity: Up to 20 samples
- Readout: 2 line by 24-character vacuum fluorescent display
- Units: mOsm/kg H2O
- Range: 0 to 2000 mOsm/kg H2O
- Resolution: 1 mOsm/kg H2O
- Communications: On-board printer, DTE EIA-232/V.24 (RS-232) serial port and optional barcode scanner
- Performance at Reference Conditions1
- Linearity: ±3 mOsm/kg between 0 and 300 mOsm/kg H2O; less than ±1% above 300 mOsm/kg H2O
- Repeatability: 0 to 400 mOsm: ±3 mOsm/kg (1 S.D.) 400 to 2000 mOsm: ±0.75% (1 S.D.)
- Drift: Less than 1 mOsm/kg H2O per month
- Performance Over Operating Conditions
- Temperature Effects: Less than 1 mOsm/kg H2O for every 5°C (9°F) ambient temperature change
- Operating Conditions Temperature: 18°C to 35°C (64°F to 95°F)
- Humidity: 30 to 80% relative humidity (non-condensing)
- Storage Temp.: -40°C to +45°C (-40°F to +113°F)
- Start-up Time: Immediately from stand-by; under 5 minutes from power-on
- Test Time: 90 seconds per sample, typical
- Sample Throughput: 35 to 40 per hour
- Dimensions 29.0cm x 40.6 cm x 31.0 cm, (11.4" H x 16.0" W x 12.2" D)
- Weight Net: 10.0 kg (22.0 lbs.), Shipping: 15.5 kg (34.0 lbs.)
YSI Biochemistry Analyzer
Sold out
Contact for price
BLE2000059
- Benchtop: Yes
- Certifications ETL, RoHS, CE
- Compliance21 CFR, Part 11
- GAMP® 5
- Connectivity / Communications Ethernet, USB
- Graphic Display: Yes
- Measurement Range Glucose: 0.05-25 g/L, Lactate: 0.05-2.70 g/L, Glutamate: 15-1460 mg/L, Glutamine: 30-1169 mg/L, Glycerol: 0.75-40 g/L, Xylose: 0.5-30 g/L, Choline: 5-450 mg/L, Hydrogen Peroxide: 3-300 mg/L, Sucrose: 0.1-25 g/L, Ethanol: 0.04-3.2 g/L, Ethanol-HC: 0.5-40 g/L, Methanol: 0.1-2.5 g/L, Lactose: 0.05-25 g/L, Galactose: 0.1-25 g/L
- Memory Yes
- Operating Temperature 15-35°C
- Parameters Measured Glucose, Lactate, Glutamate, Glutamine, Glycerol, Xylose, Choline, Hydrogen Peroxide, Sucrose, Ethanol, Methanol, Lactose, Galactose
- Power 100-240 VAC, 50-60 Hz
- Precision Application specific, typical CV <2%
- Unit of Measure mg/dL, mg/L, g/L, %, mmol/L
YSI 2900D Biochemistry Analyzer
Sold out
Contact for price
BLE1900447
- Benchtop: Yes
- Certifications ETL, RoHS, CE
- Compliance21 CFR, Part 11
- GAMP® 5
- Connectivity / Communications Ethernet, USB
- Graphic Display: Yes
- Measurement Range Glucose: 0.05-25 g/L, Lactate: 0.05-2.70 g/L, Glutamate: 15-1460 mg/L, Glutamine: 30-1169 mg/L, Glycerol: 0.75-40 g/L, Xylose: 0.5-30 g/L, Choline: 5-450 mg/L, Hydrogen Peroxide: 3-300 mg/L, Sucrose: 0.1-25 g/L, Ethanol: 0.04-3.2 g/L, Ethanol-HC: 0.5-40 g/L, Methanol: 0.1-2.5 g/L, Lactose: 0.05-25 g/L, Galactose: 0.1-25 g/L
- Memory Yes
- Operating Temperature 15-35°C
- Parameters Measured Glucose, Lactate, Glutamate, Glutamine, Glycerol, Xylose, Choline, Hydrogen Peroxide, Sucrose, Ethanol, Methanol, Lactose, Galactose
- Power 100-240 VAC, 50-60 Hz
- Precision Application specific, typical CV <2%
- Unit of Measure mg/dL, mg/L, g/L, %, mmol/L
YSI 2700-D SELECT Biochemistry Analyzer
Contact to Purchase
Specifications
Analyzer
- Aspirated sample volume: User selects 5 to 65 microliters
- Analysis time: 60 seconds
- Precision: <2% cv, n=10
- Linearity: ±5%, calibration value to range maximum
- Calibration: User selects frequency Size: 35.6 x 25.4 x 35.6 cm, 11.4 kg (14 x 10 x 14 inches, 25 lbs)
- Working environment: 15 to 35°C ambient temperature, 10 to 90% relative humidity (noncondensing)
- Power: 110 to 120 volts, 50/60 Hz, 1.0 amp, 3-wire grounded. 220 to 240 volts, 50/60 Hz, 3-wire grounded
- Battery backup: Rechargeable Ni-Cad batteries to back up RAM.
Monitor
- Sample inlet tubing: Silicone, 0.08" OD x 0.02" ID; Volume: 5.1 microliters per inch
- Inlet channel pump tubing: PharMed® 0.13" OD x 0.035" ID Valve tubing: 0.03" ID Wasteline tubing: Silicone, 0.16" OD x 0.10" ID
- Nominal flow rate (inlet line): 100 to 2500 microliters per minute (±8% @ ±6 PSI)
- Sample interval: 2 minutes to 1,000 hours
YSI 2700-D Biochemistry Analyzer
Sold out
Free shipping available
BLE1900059
Specifications
Analyzer
- Aspirated sample volume: User selects 5 to 65 microliters
- Analysis time: 60 seconds
- Precision: <2% cv, n=10
- Linearity: ±5%, calibration value to range maximum
- Calibration: User selects frequency Size: 35.6 x 25.4 x 35.6 cm, 11.4 kg (14 x 10 x 14 inches, 25 lbs)
- Working environment: 15 to 35°C ambient temperature, 10 to 90% relative humidity (noncondensing)
- Power: 110 to 120 volts, 50/60 Hz, 1.0 amp, 3-wire grounded. 220 to 240 volts, 50/60 Hz, 3-wire grounded
- Battery backup: Rechargeable Ni-Cad batteries to back up RAM.
Monitor
- Sample inlet tubing: Silicone, 0.08" OD x 0.02" ID; Volume: 5.1 microliters per inch
- Inlet channel pump tubing: PharMed® 0.13" OD x 0.035" ID Valve tubing: 0.03" ID Wasteline tubing: Silicone, 0.16" OD x 0.10" ID
- Nominal flow rate (inlet line): 100 to 2500 microliters per minute (±8% @ ±6 PSI)
- Sample interval: 2 minutes to 1,000 hours
Click 'buy now' through our site to checkout with free shipping! We accept major credit cards
Magellan Instruments Tandem PRO Gas Analyzer
SN 0381-PRO
LIKE NEW CONDITION!!!! Tested and ready to ship. Includes a 30 Day Money Back Guarantee!!!
The Tandem PRO is a self-contained O2 & CO2 gas analyzer. The PRO system comes with an internal gas pump and programmable display. It includes calibration functions, error reporting and dual 4-20mA outputs. An RS232 output is included for integration into control systems.
The Tandem PRO is incredible value and offers you all these benefits:
- Greater understanding of your cells and processes
- Physiological state measurement on-line
- Scale-up and scale-down predictions
- Batch variation studies: feature analysis
- Metabolic flux analysis and mass-balance calculations
- Accurate fed-batch control
- Repeatable event decisions: induction, infection, harvesting etc.
- Batch variation studies: anomaly analysis
- Metabolic activity based feeding
- Repeatable event decisions: induction, infection, harvesting etc.
- On-line information, allows real-time calculation of RQ, CER, OUR, growth rate, KLa etc.
- 0-10V and 4-20mA, with RS232 on PRO & Multiplex
- Integrates to any reactor size (250ml – 100m3)
Nova Biomedical Bioprofile CDV Cell Density and Viability Analyzer
Contact for price
BLE1800173
Nova Biomedical Bioprofile 100
The BioProfile 100 offers eight measured tests including
- glutamine,
- glutamate,
- glucose,
- lactate,
- ammonium,
- pH,
- sodium
- potassium,
- calculated osmolality.
Nova Biomedical Bioprofile 300 Automated Chemistry Analyzer
Contact to purchase
SN T03709010
This system offers measurement ranges specifically suited to bacterial fermentation. Features automatic calibration, one-button analysis and batch processing capability.
- Nutrients/Metabolites: Glucose, Lactate, Ammonium, Acetate, Phosphate, also reports phosphorus
- Acid/Base Status: pH
- Electrolytes: Sodium, Potassium
- Calculated Parameter: Osmolality
Nova Biomedical Bioprofile 400 Analyzer
Contact to purchase
BLE1800341/BLE1800342
- Nutrients/Metabolites: Glutamine, Glutamate, Glucose, Lactate, Ammonium
- Acid/Base Status: pH, PO2, PCO2
- Electrolytes: Sodium, Potassium
- Calculated Parameter: Osmolality, Air Saturation, CO2, Saturation, HCO3
Nanodrop Technologies ND-1000 Spectrophotometer
Sold out
Free shipping available
BLE1900401
The NanoDrop® ND-1000 UV-Vis Spectrophotometer enables highly accurate analyses of 1 ul samples with remarkable reproducibility.
The full spectrum (220nm-750nm) spectrophotometer utilizes a patented sample retention technology that employs surface tension alone to hold the sample in place. This eliminates the need for cumbersome cuvettes and other sample containment devices and allows for clean up in seconds.
You’ll find yourself making fewer dilutions and taking more readings than ever before, essentially becoming a more quantitative laboratory.
In addition, the NanoDrop 1000 Spectrophotometer has the capability to measure highly concentrated samples without dilution (50X higher concentration than the samples measured by a standard cuvette spectrophotometer).
NanoDrop® ND-1000 UV-Vis Spectrophotometer Benefits:
- Small Samples - Designed for 1 ul samples
- Large dynamic range - Measures 2-3700 ng/ul (dsDNA) on a single sample. No need to change out cuvettes or caps.
- High absorbance capability - 50 times that of traditional spectrophotometers
- No Dilutions for most samples
- No extra costs for consumables
- Full Spectrum (220-750nm)
- 10 second measurement time
- No cuvettes or capillaries
- Sample is recoverable
- Small size (size of a tissue box)
- Easy set up (plug and play)
NanoDrop® ND-1000 UV-Vis Spectrophotometer Applications:
- Nucleic acid concentration and purity of nucleic acid samples up to 3700 ng/ul (dsDNA) without dilution
- Fluorescent dye labeling density of nucleic acid microarray samples
- Purified protein analysis (A280) up to 100 mg/ml (BSA)
- Expanded spectrum measurement and quantitation of fluorescent dye labeled proteins, conjugates, and metalloproteins
- Bradford Assay analysis of protein
- BCA Assay analysis of protein
- Lowry Assay analysis of protein
- Pierce Protein 660 nm Protein Assay
- Cell density measurements
- General UV-Vis Spectrophotometry
Click 'buy now' through our site to checkout with free shipping! We accept major credit cards
Nanodrop Technologies ND-1000 Spectrophotometer with Software Loaded PC
Sold out
Free shipping available
BLE1900401
Includes Software Loaded PC
The NanoDrop® ND-1000 UV-Vis Spectrophotometer enables highly accurate analyses of 1 ul samples with remarkable reproducibility.
The full spectrum (220nm-750nm) spectrophotometer utilizes a patented sample retention technology that employs surface tension alone to hold the sample in place. This eliminates the need for cumbersome cuvettes and other sample containment devices and allows for clean up in seconds.
You’ll find yourself making fewer dilutions and taking more readings than ever before, essentially becoming a more quantitative laboratory.
In addition, the NanoDrop 1000 Spectrophotometer has the capability to measure highly concentrated samples without dilution (50X higher concentration than the samples measured by a standard cuvette spectrophotometer).
NanoDrop® ND-1000 UV-Vis Spectrophotometer Benefits:
- Small Samples - Designed for 1 ul samples
- Large dynamic range - Measures 2-3700 ng/ul (dsDNA) on a single sample. No need to change out cuvettes or caps.
- High absorbance capability - 50 times that of traditional spectrophotometers
- No Dilutions for most samples
- No extra costs for consumables
- Full Spectrum (220-750nm)
- 10 second measurement time
- No cuvettes or capillaries
- Sample is recoverable
- Small size (size of a tissue box)
- Easy set up (plug and play)
NanoDrop® ND-1000 UV-Vis Spectrophotometer Applications:
- Nucleic acid concentration and purity of nucleic acid samples up to 3700 ng/ul (dsDNA) without dilution
- Fluorescent dye labeling density of nucleic acid microarray samples
- Purified protein analysis (A280) up to 100 mg/ml (BSA)
- Expanded spectrum measurement and quantitation of fluorescent dye labeled proteins, conjugates, and metalloproteins
- Bradford Assay analysis of protein
- BCA Assay analysis of protein
- Lowry Assay analysis of protein
- Pierce Protein 660 nm Protein Assay
- Cell density measurements
- General UV-Vis Spectrophotometry
Click 'buy now' through our site to checkout! We accept major credit cards
Agilent 2100 Bioanalyzer Including G2938A Chip Reader, VWR MV1 Mini Vortexter, Chip Priming Station, PC, Keyboard & Mouse
Sold out
BLE1700256
System Includes:
Agilent 2100 Bioanalyzer
Agilent G2938A Chip Rader
VWR MV1 Mini Vortexter
Agilent Chip Priming Station (Like new condition, in original box)
Excellent working condition, tested and ready to ship. Includes a 30 Day Money Back Guarantee!!!
- Weight 10 kg (22 lbs)
- Dimensions (w × d × h)162 × 412 × 290 mm (6.4 × 16.2 × 11.4 in)
- Line voltage 100-240 VAC
- Line frequency 50-60 Hz
- Power consumption 60 VA
- Ambient operating temperature15 – 27 °C (59 – 80 °F)
- Safety standards: IEC, CSA, ULInstallation Category II, Pollution Degree 2, Laser Class 1
Click 'buy now' through our site to checkout! We accept major credit cards.
Hewlett Packard 8453 UV Vis Spectrophotometer with Software Loaded PC, Monitor, Keyboard and Mouse
Sold out
Contact to purchase
BLE1700074
System includes:
- ThinkCentre PC loaded with Windows 10
- Installed Chemstation software v. b.05.04(8)
- Monitor
- Keyboard & Mouse
The Agilent 8453 UV-Visible Spectrophotometer G1103A uses a photodiode array (PDA) for simultaneous measurement of the complete ultra-violet to visible light spectrum in less than one second. The PDA technique brings exceptional reliability and repeatability. Using Agilent ChemStation software you get powerful data analysis and data archival to ensure compliance with good laboratory practices (GLP) and pharmacopoeia requirements. The HP 8453 spectrophotometer is a single-beam, microprocessor-controlled UV-Vis spectrophotometer with collimating optics, 190-1100nm wavelength range, 1nm slit width, ±0.5nm wavelength accuracy, less than 0.03 percent stray light, -10C to 120C temperature set range.
- Features:Fast results, UV-Vis spectral acquisition and analysis in less than 1 second
- Excellent reproducibility, stable optics, low noise electronics, no moving parts
- Simple operation, task-oriented and application software (not included), direct access to cells and cell holder
- Effortless servicing, pre-aligned deuterium and tungsten lamps exchanged easily
- Good laboratory practices (GLP), self-test and revisions built into the software (not included)/firmware
- Pharmaceutical complianc regulated software for European and US pharmacopoeia
- 8 position 1cm sqaure cell holder.
Wescor Vapro Vapor Pressure Osmometer
Sold out
Contact to Purchase
SN 55200830
Excellent Condition, tested and ready to ship. Includes 30 day money back guarantee!
- Sample Volume 10 uL nominal
- Measurement Range Typically 0 to 3200 mmol/kg @ 25C ambient
- Measurement Time 75 seconds
- Resolution 1 mmol/kg
- Repeatability Linearity Readout Standard deviation = 2 mmol/kg, 2%
- Operating Temperature 15 to 37C ambient
- Calibration Automatic using Opti-mole™ osmolality standards (Not Included)
Thermo Scientific LTQ Orbitrap XL with Proxeon Easy-nLC II
Sold out
Protein Identification
- High mass accuracy lowers false positive rates
- Parallel acquisition mode optimizes productivity
- High MS and MS/MS sensitivity, wide dynamic range and fast cycle times increase protein identifications
- HCD collision cell provides high fragmentation efficiency combined with high sensitivity for the reporter and fragment ions of the peptide sequence
- Reliable identification and quantification in one experiment
- High mass accuracy and high resolution leads to high confidence de novo sequencing results
- Multiple collision modes (CID and HCD) provide comprehensive structural information
- High mass accuracy, sensitivity, and dynamic range enable reliable profiling of low-abundance
- metabolites in complex mixtures
Beckman Coulter VI-Cell XR Cell Viability Analyzer
Sold out
Contact for Price
SN AM24149
Excellent condition, tested and ready to ship. Includes 30 day money back guarantee!
Features
- Viability testing
- Total cell concentration
- Total viable cell concentration
- Mean cell size
- Real time cellular images
- Bioprocess monitoring
- Validated reagents
- Convenient reagent pack
Benefits
- Fast automated cell staining & cell counting (< 2.5 mins) with customizable cell types
- Distinguishes between viable and non-viable cells across a wide range of cell types with confidence
- Software with pre-programmed cell types (CHO, yeast, hybridoma) as well as option to design custom analysis type for specific cell lines
- Automated cell counting, staining & disposal
- Operator bias eliminated with automated protocols
Agilent G2938A 2100 Series Bioanalyzer with Priming Station, IKA MS3 Basic Shaker, PC, Monitor Keyboard & Mouse
Sold out
Contact Us to Purchase
The Agilent 2100 Bioanalyzer system provides sizing, quantitation and quality control of DNA, RNA, proteins and cells on a single platform, providing high quality digital data.
- Two assay principles - electrophoresis and flow cytometry
- Ready-to-use assays and pre-packaged reagent kits
- Minimal sample consumption (1-4 µL)
- Easy to use – load the chip, press “start“, the instrument does the rest!
- Digital data for convenient analysis, archiving and storage
- Contamination-free switch of methods
Shimadzu ON-LINE TOC-VCSH Total Organic Carbon Analyzer with ASI-V Auto Sampler
Sold out
SN H51104535248cs
Offered Shimadzu Corporation TOC-VCSH Total Organic Carbon Analyzer with 40 mL vials x 68 ASI-V Auto Sampler Complete working System.
This system tested and is in excellent condition!
The functionality for continuous automatic measurement has bee added to the ability of the combustion catalytic oxidation/NDIR TOC-V Series to perform high-performance, high sensitivity measurement of organic substances.
The On-line TOC-VCSH can be used for Continuous automatic high-sensitivity monitoring of water samples such as pure water and tap water.
Combines Combustion Catalytic Oxidation at 680°C and NDIR Method
Combustion catalytic oxidation at 680°C oxidizes even persistent or insoluble organic compounds. This method accurately measures any type of organic substance not affected by interfering substances or the sample properties such as pH or conductivity.
Easy Maintenance
Combustion catalytic oxidation at 680°C eliminates the need for oxidizing reagents, saving the tasks of procuring and preparing reagents. No special draining operations are needed.
Support Software for Pharmaceutical Water Management Applications
The On-line TOC-VCSH incorporates software for automatically performing tests specified by Japanese Pharmacopoeia (resolution test) and USP (system suitability test). Combining the On-line TOC-VCSH with an OCT-1 (optional) enables fully automatic testing; setting the reagent is all that is required.
Wide Variety of TOC Measurement Methods
NPOC, IC, TC and TOC (TC-IC) measurements are possible with the ON-LINE TOC-VCSH. TN measurement is also possible by adding an optional product. TOC and TN can be measured simultaneously.
Main Applications
- Management of pharmaceutical water
- Management of ultrapure and recycled water for the semiconductor industry
- Management of mains water
- l Impurity contamination management for all types of water used at plants (cooling water, recycled water, and boiler water)
- Measured items NPOC (TOC by IC subtraction using acid sparging), TC, IC, TOC (TC-IC), TN (optional TNM-1 required)
- Measurement method 680ºC combustion catalytic oxidation/NDIR method
(when TNM-1 is connected)
- Measurement range TC: 0-500 ìg/L to 0-25,000 mg/L variable
- Measurement cycle Approx. 5 to 999 minutes (for NPOC measurement)
- Number of measurement channels 1 channel
- Reproducibility CV 1.5% max.
- Linearity ±2% F.S. max.
- Zero stability ±2% F.S. max. per day
- Span stability ±2% F.S. max. per day (ambient temperature fluctuations within 5ºC)
- Calibration cycle Variable in the range 1 to 999 hours
- Sample injection method Automatic injection using syringe pump/slider
- Sample injection volume Variable in the range 10 to 2,000 uL
- Sample dilution function Diluted in syringe; dilution factor: 2 to 50
- IC pretreatment Automatic acidification and sparging
- Carrier gas High-purity air or oxygen (1 ppm max. of CO, CO2, or HC)
Supply pressure: Approx. 600 kPa
Flow rate: 150 mL/min (230 mL/min with sparging)
- Measurement value output Analog output: Select from 4 to 20mA, 0 to 16mA (insulation, load resistance: 750Ù max.), and 0 to 1VDC RS-232C: Baud rate; 9,600 bps, Data length; 8 bits, Parity; none, Stop bits; 1
- Alarm output Measurement value upper limit and upper upper limit alarms, system error alarm: No-voltage contact output (maximum: 5VA, 0.1A, 50V)
- Control input Remote stopping and starting of sample measurement and calibration
- Sample conditions Flow rate: Approx. 0.1 to 1 L/min
- Sample volume: 5 to 7 mL per measurement
- Temperature: 0 to 90ºC
- Ambient temperature 5 to 35ºC
- Power supply AC 100 - 127V ±10% MAX 800VA 50/60 Hz
- Dimensions Approx. 440 (W) x 560 (D) x 460 (H) mm (excluding protrusions)
- Weight Approx. 40 kg
- have a well-sealed septum that can be easily replaced with the screw cap.
- The sampling needle is optimized for sample extraction from highly sealed vials and for sparging.
- Changing analysis conditions or adding sample vials during analysis is simple. System operation and carrier gas flow can be automatically stopped on completion of measurements.
- Creating multiple calibration curves and selecting the optimal curve for samples with significantly differing concentrations allows these samples to be analyzed in a single run.
- Rinsing both external and internal surfaces of the sampling needle prevents carryover between samples.
- Vial types: 40mL
- Number of vials: 40mL X 68
- Vial Septum With dedicated septum
- Sample sparging OK (If the external sparging kit is used)
- Dimensions Approx. (W)370 x (D)540 x (H)490mm
- Weight Approx. 14 kg
Agilent 8453 Single Cuvette UV Vis Spectrophotometer with Software Loaded PC, Monitor, Keyboard and Mouse
Sold out
Contact to purchase
BLE1700172
The Agilent 8453 UV-Visible Spectrophotometer G1103A uses a photodiode array (PDA) for simultaneous measurement of the complete ultra-violet to visible light spectrum in less than one second. The PDA technique brings exceptional reliability and repeatability. Using Agilent ChemStation software you get powerful data analysis and data archival to ensure compliance with good laboratory practices (GLP) and pharmacopoeia requirements. The HP 8453 spectrophotometer is a single-beam, microprocessor-controlled UV-Vis spectrophotometer with collimating optics, 190-1100nm wavelength range, 1nm slit width, ±0.5nm wavelength accuracy, less than 0.03 percent stray light, -10C to 120C temperature set range.
Features:
Fast results, UV-Vis spectral acquisition and analysis in less than 1 second
Excellent reproducibility, stable optics, low noise electronics, no moving parts
Simple operation, task-oriented and application software (not included), direct access to cells and cell holder
Effortless servicing, pre-aligned deuterium and tungsten lamps exchanged easily
Good laboratory practices (GLP), self-test and revisions built into the software (not included)/firmware
Pharmaceutical complianc regulated software for European and US pharmacopoeia
8 position 1cm sqaure cell holder.
Advanced Instruments 3250 Osmometer
Sold out
Contact for price
BLE2000077
GOLD STANDARD PERFORMANCE
The Model 3250 uses a 200-250 μL sample volume, provides the best accuracy and precision of ANY osmometer. Sample test time is 2-3 minutes depending on the operating range
PROVEN RELIABILITY
The 3250 system incorporates over 50 years of applied technology and expertise in the field of osmometry and is ideal for laboratories seeking greater control, minimal downtime, and higher productivity
EASY TO USE
With features including a menu-driven display with push-button design, automatic calibration, and onboard statistical analysis, the 3250 combines world-class performance in a user friendly package
WIDE OPERATING RANGE
The Model 3250 offers the widest measurement range of any osmometer of 0-4000 mOsm. Select from 2 calibrated operating ranges depending on your sample type
VERSATILE SAMPLE PROCESSING
The 3250’s test parameters can be optimized based on the sample type, making it an ideal research osmometer for analyzing a wide variety of complex aqueous mixtures
FLEXIBLE REPORTING OPTIONS
The 3250 provides an onboard printer, optional bar code scanner, internal memory storage of test results, and the ability to connect to LIS or data management systems
Nova Biomedical Bioprofile Flex Analyzer for Sale
Sold out
Please call for pricing
Excellent condition. Includes 30 day money back guarantee!!!!
ioProfile is a chemistry/cell viability modular instrument that measures up to 15 key cell culture attributes. By combining as many as five separate instruments into one easy-to-use instrument, BioProfile FLEX simplifies workflow and saves time, labor, and operating cost versus multiple instruments.
Applications of BioProfile FLEX include:
- Monitoring the progress of bioreactor runs
- Determining consumption and production of key metabolites
- Identification of growth-limiting nutrients
- Design of feeding strategies
- Calibration of bioreactor probes
- Measurement of cellular respiration
- Balancing media electrolytes
- Control levels of waste product.
- Sample Analysis Time: 2.5 minutes (Gases only – PO2 + PCO2)4.0 minutes
(Chemistry/Gas & Osmolality)6.25 minutes
(All 15 tests)
- Operating Temperature Range: 15-30°C (59-86°F)
- Operating Relative Humidity Range: 20-85%
- Sample Size: 1 mL (for all modules)
- Sampling Options: Individual via syringe/cup
- Automated batch using 20-position sampling tray
- On-line, automated from up to ten bioreactors
- Electrical Requirements: 90-264 VAC, 50 to 60 Hz (Universal Power Supply)
- System Size: Height: 20 in (50 cm) Width: 26 in (66 cm) Depth: 20 in (50 cm)
- System Weight: Analyzer: 94 lbs (42.6 kg) without reagents
- Host Computer Monitor/CPU: 41.5 lbs (18.8 kg)
- Safety Certifications: TUV: IEC 61010-1:2001
- Quality Systems Certifications: TUV: ISO9001:2000 FDA Registered, OPC Compliant, PAT Compatible, 21 CFR Part 11 Compliant
Chemistry/Gas Module AssayMeasurement Range ResolutionMethod
- Glucose 0.2–30.0 g/L*0.01g/L Biosensor
- Lactate 0.2–10.0 g/L*0.01g/L Biosensor
- Glutamine 0.2–12.0 mmol/L*0.01 mmol/L Biosensor
- Glutamate 0.2–12.0 mmol/L*0.01 mmol/L Biosensor
- Ammonium 0.2–25.0 mmol/L0.01 mmol/L Direct ISE
- pH5.000–8.0000.001 Direct ISE
- PCO23.0–300.0 mmHg0.1 mmHg Direct ISE
- PO23.0–800.0 mmHg0.1 mmHg Clarke Electrode
- Sodium 40–220 mmol/L0.1 mmol/L Direct ISE
- Potassium 1.0–100.0 mmol/L0.01 mmol/L Direct ISE
- Calcium 0.10–10.0 mmol/L0.01 mmol/L Direct ISE Calculated Tests:O2 Saturation; CO2 Saturation; Temp. Corrected pH, PCO2, PO2
- *Ranges Reflect User Selectable 1:2 Dilution
- Osmolality ModuleAssayMeasurement Range ResolutionMethod
- Osmolality0–1500 mOsm/kg1 mOsm/kgFreezing PointCell Density/Viability Module AssayMeasurement Range ResolutionMethod
- Cell Diameter8 – 50 μmN/A Digital Imaging
- Detectable Density 50,000 – 100,000,000cells/mL**N/A Digital Imaging
- Viability0 – 100%N/A Digital Imaging Phosphate Module Measurement Range 0.20-10 mmol/L
- Sample Size 500 µL**Ranges Reflect User Selectable 1:2, 1:4, 1:5, 1:10 Dilution
- IgG Module Measurement Range: 0.10–10.00 g/L* *Ranges Reflect User Selectable 1:2 Dilution
Advanced Instruments 3320 Osmometer with Optional Printer and Optional EZ Eject Sampler
Sold out
BLE1800328Please contact to purchase
Excellent condition, tested and ready to ship. Includes 30 day money back guarantee!
Advanced Instruments Osmometer, Model 3320, for Osmolality Measurement
The Advanced Instruments Model 3320 Micro Osmometer determines the osmolality of solutions using freezing point depression (FPD). It is Ideal for serum, urine or other bodily fluids in clinical applications; and media or formulations in pharmaceutical, biotech or industrial applications.
Automated, single sample, designed to process a 20 μL sample, and one-minute test time, allows the Model 3320 to provide the best accuracy and precision in the market today.
- 20 μL is ideal for applications where the sample quantity is limited.
- Unparalleled ease of use
- Internal diagnostics
- Ergonomic, compact design
- On-board statistical analysis
- Results recall the last 30 tests
- Multi-language operation
- Automated calibration
- Password lock out
- Hot-Line® Technical Service available 24/7Advanced Instruments also supplies ControLine Products
- Clinitrol™ 290 mOsmol Reference Solution
- Protinol® Protein-based Controls
- Renol™ Urine Osmolality Contols
- Linearity Osmolality Controls
Performance at Reference Conditions
Linearity: Less than ±1% from a straight line over calibrated range
Repeatability: 0 to 400 mOsm: ±2 mOsm/kg (1 S.D.) 400 to 2000 mOsm: ±0.5% (1 S.D.)
Drift: Less than 1 mOsm/kg H2O per month
Performance Over Operating Conditions
Temperature Effects: Less than 1 mOsm/kg H2O for every 5°C (9°F) ambient temperature change
Operating ConditionsTemperature: 18°C to 35°C (64°F to 95°F)
Humidity: 5 to 80% relative humidity (non-condensing)
Storage Temp.: -40°C to +45°C (-40°F to +113°F)
Start-up Time: 30 seconds from power-on
Test Time: 60 seconds
Dimensions
35.5 cm x 35.5 cm x 38.1 cm
(14.0" H x 14.0" W x 15.0" D)
Weight
Net: 6.1 kg (13.4 lbs.)
Shipping: 11.4 kg (25.0 lbs.)
Wyatt Technologies Dawn Helios II (Model WH2-09)
Sold out
Contact for price
BLE1900527
The DAWN® HELEOS® II is the premier Multi-Angle static Light Scattering (MALS) detector for absolute characterization of the molar mass and size of macromolecules and nanoparticles in solution. The DAWN offers the highest sensitivity, the widest range of molecular weight, size and concentration, and the largest selection of configurations and optional modules for enhanced capabilities.
The DAWN is most often used in conjunction with Gel Permeation Chromatography (GPC-MALS) or Size Exclusion Chromatography (SEC-MALS) or Field-Flow Fractionation (FFF-MALS) to determine distributions of mass, size and composition independent of column calibration by reference standards.
Included with each DAWN is a copy of ASTRA, the most versatile software package available for analysis of online multi-angle and dynamic light scattering.
Measurements
Molar Mass Range 200 Da to 1000 MDa1
Molecular Size Range (rg)≈ 10 to 500 nm1, up to 1000 nm with shape-specific models
Molecular Size Range (Rh,with WyattQELS DLS module or DynaPro NanoStar) Depends on the scattering angle:
In flow mode, 0.5 nm – 300 nm1,2
batch mode, 0.5 nm – 1 µm1
Sensitivity 10 ng of 100 kDa polystyrene in THF3
200 ng of BSA in PBS4
Fluidics
Mobile Phase Compatibility All-solvent compatible (aqueous and organic). Wetted materials are 316 stainless steel, fused silica or F2 glass, and Kalrez.
Optics
Detectors
MALS Detectors High-gain, high dynamic range, static light scattering detectors at 18 angles.
Auxiliary Detectors Laser monitor for stabilization feedback; forward transmission monitor to correct signals for absorbing samples and to assess data quality.
A/D Resolution 24 bit (detector dynamic range > 16,000,000) -
WyattQELS dynamic light scattering module installs directly inside the DAWN chassis.
DLS Detector (optional)
Alternatively, the optical fiber pickup of the DynaPro NanoStar cuvette-based DLS instrument may be installed in the DAWN.Laser Properties Laser Wavelength658 nm; 785 nm available for fluorescence reduction (with lower sensitivity than 658 nm) Laser Power ControlProgrammable 10% - 100%Flow CellsFused Silica, optimal for solvent refractive index less than 1.50
F2, optimal for solvent refractive index above 1.50Temperature OptionsAmbient
Heated/Cooled (HC) -15°C to +150°C
Ultra-High-Temperature (UHT) ambient to +210°CElectronics Analog Inputs4 differential analog inputs with 24 bit resolution. Input range -10 V to +10 V Analog Outputs2 analog outputs from user settable measurements channels -10 V to +10 V Other Inputs/OutputsAlarm in, Alarm retransmit, Auto-Inject in, Auto inject contact closure, Recycle in, Recycle valve power Computer Interface Ethernet Transmission Rate36.6 to 0.0001 Hz Front Panel Display162.5 mm, 16-bit, high resolution touch screen displays signal graphs, instrument settings and diagnosticsDimensions60 cm (L) x 36 cm (W) x 23 cm (H)
Wyatt Technologies Dawn Helios II (Model WH-02)
Sold out
Free shipping available
BLE2000163
The DAWN® HELEOS® II is the premier Multi-Angle static Light Scattering (MALS) detector for absolute characterization of the molar mass and size of macromolecules and nanoparticles in solution. The DAWN offers the highest sensitivity, the widest range of molecular weight, size and concentration, and the largest selection of configurations and optional modules for enhanced capabilities.
The DAWN is most often used in conjunction with Gel Permeation Chromatography (GPC-MALS) or Size Exclusion Chromatography (SEC-MALS) or Field-Flow Fractionation (FFF-MALS) to determine distributions of mass, size and composition independent of column calibration by reference standards.
Measurements
Molar Mass Range 200 Da to 1000 MDa1
Molecular Size Range (rg)≈ 10 to 500 nm1, up to 1000 nm with shape-specific models
Molecular Size Range (Rh,with WyattQELS DLS module or DynaPro NanoStar) Depends on the scattering angle:
In flow mode, 0.5 nm – 300 nm1,2
batch mode, 0.5 nm – 1 µm1
Sensitivity 10 ng of 100 kDa polystyrene in THF3
200 ng of BSA in PBS4
Fluidics
Mobile Phase Compatibility All-solvent compatible (aqueous and organic). Wetted materials are 316 stainless steel, fused silica or F2 glass, and Kalrez.
Optics
Detectors
MALS Detectors High-gain, high dynamic range, static light scattering detectors at 18 angles.
Auxiliary Detectors Laser monitor for stabilization feedback; forward transmission monitor to correct signals for absorbing samples and to assess data quality.
A/D Resolution 24 bit (detector dynamic range > 16,000,000) -
WyattQELS dynamic light scattering module installs directly inside the DAWN chassis.
DLS Detector (optional)
Alternatively, the optical fiber pickup of the DynaPro NanoStar cuvette-based DLS instrument may be installed in the DAWN.Laser Properties Laser Wavelength658 nm; 785 nm available for fluorescence reduction (with lower sensitivity than 658 nm) Laser Power ControlProgrammable 10% - 100%Flow CellsFused Silica, optimal for solvent refractive index less than 1.50
F2, optimal for solvent refractive index above 1.50Temperature OptionsAmbient
Heated/Cooled (HC) -15°C to +150°C
Ultra-High-Temperature (UHT) ambient to +210°CElectronics Analog Inputs4 differential analog inputs with 24 bit resolution. Input range -10 V to +10 V Analog Outputs2 analog outputs from user settable measurements channels -10 V to +10 V Other Inputs/OutputsAlarm in, Alarm retransmit, Auto-Inject in, Auto inject contact closure, Recycle in, Recycle valve power Computer Interface Ethernet Transmission Rate36.6 to 0.0001 Hz Front Panel Display162.5 mm, 16-bit, high resolution touch screen displays signal graphs, instrument settings and diagnosticsDimensions60 cm (L) x 36 cm (W) x 23 cm (H)
Click 'buy now' through our site to checkout with free shipping! We accept major credit cards
Agilent 8453 G1103A Spectrophotometer with PC, Monitor, Keyboard and Mouse
Sold out
Contact to purchase
BLE1900156
Agilent Technologies 8453 Single Cuvette Ultraviolet Visible Spectrophotometer with Software loaded PC, Monitor, Keyboard and Mouse
Sold out
Contact to purchase
BLE1700171
Includes Windows 10 ThinkCentre PC loaded with Chemstation B.05.04(8)
The Agilent 8453 UV-Visible Spectrophotometer G1103A uses a photodiode array (PDA) for simultaneous measurement of the complete ultra-violet to visible light spectrum in less than one second. The PDA technique brings exceptional reliability and repeatability. Using Agilent ChemStation software you get powerful data analysis and data archival to ensure compliance with good laboratory practices (GLP) and pharmacopoeia requirements. The HP 8453 spectrophotometer is a single-beam, microprocessor-controlled UV-Vis spectrophotometer with collimating optics, 190-1100nm wavelength range, 1nm slit width, ±0.5nm wavelength accuracy, less than 0.03 percent stray light, -10C to 120C temperature set range.
Features:
Fast results, UV-Vis spectral acquisition and analysis in less than 1 second
Excellent reproducibility, stable optics, low noise electronics, no moving parts
Simple operation, task-oriented and application software (not included), direct access to cells and cell holder
Effortless servicing, pre-aligned deuterium and tungsten lamps exchanged easily
Good laboratory practices (GLP), self-test and revisions built into the software (not included)/firmware
Pharmaceutical complianc regulated software for European and US pharmacopoeia
8 position 1cm sqaure cell holder.
Wyatt T-REX Optilab
Sold out
Contact for price
BLE2000085
- Range -0.0047 to + 0.0047 RIU (Differential Refractive Index Range and Sensitivity), 1.2 - 1.8 RIU (Absolute Refractive Index Range and Sensitivity)
- Type Refractive Index Detector
- Wavelength Range488 to 690 nm
YSI 2900D Biochemistry Analyzer
Sold out
Contact for price
BLE2000059
- Benchtop: Yes
- Certifications ETL, RoHS, CE
- Compliance21 CFR, Part 11
- GAMP® 5
- Connectivity / Communications Ethernet, USB
- Graphic Display: Yes
- Measurement Range Glucose: 0.05-25 g/L, Lactate: 0.05-2.70 g/L, Glutamate: 15-1460 mg/L, Glutamine: 30-1169 mg/L, Glycerol: 0.75-40 g/L, Xylose: 0.5-30 g/L, Choline: 5-450 mg/L, Hydrogen Peroxide: 3-300 mg/L, Sucrose: 0.1-25 g/L, Ethanol: 0.04-3.2 g/L, Ethanol-HC: 0.5-40 g/L, Methanol: 0.1-2.5 g/L, Lactose: 0.05-25 g/L, Galactose: 0.1-25 g/L
- Memory Yes
- Operating Temperature 15-35°C
- Parameters Measured Glucose, Lactate, Glutamate, Glutamine, Glycerol, Xylose, Choline, Hydrogen Peroxide, Sucrose, Ethanol, Methanol, Lactose, Galactose
- Power 100-240 VAC, 50-60 Hz
- Precision Application specific, typical CV <2%
- Unit of Measure mg/dL, mg/L, g/L, %, mmol/L