A straightforward, intuitive system, Emrys™ Optimizer is based on the proven Emrys™ Synthesizer and Emrys™ Creator platforms. This compact system is designed to enable multiple user access. Each chemist has control over his own vials that may be queued and processed when in turn. Sequential processing allows for individual control as well as rapid optimization of reaction conditions. The simple and flexible software with user-friendly functions such as incremental condition changes, ensure fast programming. It is as simple to program one as it is for 60 vials without the need for training or instructions. The system also allows for continuous process monitoring (time, temperature and power) and documentation. The height adjusting feet enables simple installation in a fume hood.
Specifications HEATING PROCESS
Temperature 60-250 °C (140-482 °F)
Temperature Increase 2.5 °C/sec Solvent Dependent
Pressure Range 0-20 bar (0-2 MPa, 290 PSI)
Power Range 300 W
Agitation Magnetic Stirrer
SAMPLER PROCESSOR
Processing Capacity Max. 60 Reactions/Vials
Rack Capacity Max 2, Each with 30 Vials
Reaction Volume 0.5-5 ml (0.017-0.169 fl. oz)
SYSTEM
Temperature18-32°C (64.4-89.6 °F
Humidity 20-95 %RH
Electrical Supply EU: 220-240 VAC, 50 Hz (5 A)
US: 120 VAC, 60 Hz (10 A)
JP: 100 VAC, 50/60 Hz (10 A)
Max. Power Required 1000W
Cooling Pressurised Air Supply
60-100 lit/min, 2.5-4 bar
(0.25-0.4 MPa, 36-58 PSI)
Dimensions (WxDxH) 750x610x570 mm
(29.5x24.2x22.4 in.)
Weight 62 kg (136 lbs)
- Gives Reproducible Results
- Multi-User System With Intuitive Software
- Programs up to 60 Vials in One Easy Step With Unattended Operation
- Compact and Robust Design
- Designed for Personal Safety
- Network-Ready
- Upgradeable to Manage Reagents and Kits
A straightforward, intuitive system, Emrys™ Optimizer is based on the proven Emrys™ Synthesizer and Emrys™ Creator platforms. This compact system is designed to enable multiple user access. Each chemist has control over his own vials that may be queued and processed when in turn. Sequential processing allows for individual control as well as rapid optimization of reaction conditions. The simple and flexible software with user-friendly functions such as incremental condition changes, ensure fast programming. It is as simple to program one as it is for 60 vials without the need for training or instructions. The system also allows for continuous process monitoring (time, temperature and power) and documentation. The height adjusting feet enables simple installation in a fume hood.
Specifications HEATING PROCESS
Temperature 60-250 °C (140-482 °F)
Temperature Increase 2.5 °C/sec Solvent Dependent
Pressure Range 0-20 bar (0-2 MPa, 290 PSI)
Power Range 300 W
Agitation Magnetic Stirrer
SAMPLER PROCESSOR
Processing Capacity Max. 60 Reactions/Vials
Rack Capacity Max 2, Each with 30 Vials
Reaction Volume 0.5-5 ml (0.017-0.169 fl. oz)
SYSTEM
Temperature18-32°C (64.4-89.6 °F
Humidity 20-95 %RH
Electrical Supply EU: 220-240 VAC, 50 Hz (5 A)
US: 120 VAC, 60 Hz (10 A)
JP: 100 VAC, 50/60 Hz (10 A)
Max. Power Required 1000W
Cooling Pressurised Air Supply
60-100 lit/min, 2.5-4 bar
(0.25-0.4 MPa, 36-58 PSI)
Dimensions (WxDxH) 750x610x570 mm
(29.5x24.2x22.4 in.)
Weight 62 kg (136 lbs)