Plate Reader / MicroPlate Reader
Thermo Scientific EVO300PC Evolution UV-Vis Spectrophotometer with Sotax CP7
Contact for price
BLE2000013
Accuracy ±0.004A at 1A, ±0.004A at 2A, ±0.006A at 3AÅ
Accuracy (Photometric) ±0.004A at 1A, ± 0.004A at 2A, ± 0.006A at 3A
Baseline Flatness ±0.0015A (200-800nm), 2.0nm SBW, smoothed
Beam Geometry Dual-Beam; Quartz Coated
Certifications/Compliance 21 CFR Part 11 and audit-proof IQ/OQ/PQ documentation. ISO 9001:2000
Connections RS-232
Depth (English)21 in.Depth (Metric)53cm
Description Evolution 300 PC UV-Vis Spectrophotometer, No Software
Detector Type Dual Matched Silicon Photodiodes
Drift<0.0005Abs/hr, 500 nm, 2.0 nm SBW, 2hr warm-up
Electrical Requirements 100/240V 50/60Hz
Height (English)15 in.Height (Metric)38cm
Hertz 50/60Hz
Description 300 PC, No Software
Interface Computer Control
Lamp Xenon Flash Lamp
Min. Data Interval 0.5nm
Monochromator Modified Ebert
Noise
Photometric:
0A: <0.00018 A
1A: <0.00022 A
2A: <0.00050 A
500 nm, 2.0 nm SBW, RMS
Optical Design Modified Ebert
Double beam with sample and reference cuvette/accessory positions
Pathlength (Metric)Up to 100mm cuvettes
Pharmacopoeia Compliance Testing
Resolution (Toluene in Hexane): Peak/Trough Ratio >2.0
Photometric Accuracy (60mg/L K2Cr2O7): <±0.01 A relative to calibrated sealed standard
Stray Light: <0.13 %T at 198 nm with KCl per EP
220 nm: <0.01%T NaI (behaves identically to KI for USP)
Wavelength Accuracy: ±0.20 nm (546.11 nm Hg emission line), ±0.30 nm 190–900 nm
Wavelength Repeatability: Peak separation of repetitive scanning of Hg line source <0.10 nm
Photometric Accuracy Including Standard Tolerance 1A: ±0.008 A
2A: ±0.010 A
3A: ±0.018 A
Photometric Display ±6 A
Photometric Range>4 A
Photometric Readout Absorbance, % Transmittance, % Reflectance, Concentration
Photometric Repeatability 1A: ±0.0025 A
Range (Photometric)>4A
Resolution (Toluene/Hexane)Peak/Trough >2.0 at 0.5nm SBW
Scan Ordinate Modes Absorbance, % Transmittance, % Reflectance, Concentration,
1st-4th Derivative
Scan Speed 1 to 3800nm/min
Spectral Bandwidth Variable 0.5; 1.0; 1.5; 2.0; 4.0 nm
Stray Light 198 nm: 2.9 A KCl
220 nm: 4.2 A NaI
340 nm: 4.3 A NaNO2
System Requirements At least Windows XP
Voltage 100/240V
Wavelength Accuracy ±0.20nm (546.11nm Hg emission line); ±0.3nm for 190-900nm
Wavelength Data Interval 10, 5, 2, 1, 0.5, 0.2, 0.1, 0.05 nm
Wavelength Range 190 to 1100nm
Wavelength Repeatability Standard deviation of 10 measurements <0.05 nm
Wavelength Scan Speed 3800, 2400, 1200, 600, 240, 120, 60, 30, 10, 5, 1 nm/min Intelliscan
Weight (English) 48.4 lb.Weight (Metric)22kg
Width (English) 24 in.Width (Metric)61cm
SpectraMax 340PC384 Microplate Reader including Computer
Contact to purchase
BLE140113/BLE140116
GE Healthcare Ultrospec 2100 Pro UV Visible Spectrometer
Free shipping available
BLE160867
Simple-to-use instrument for nucleic acid measurements and enzyme kinetics
Manufacturer: GE Healthcare 80-2112-21
Spectrophotometer, Spectrumeter, UV/Visible; GE Healthcare; Ultrospec 2100 pro; Classic; Provides stored routines for DNA, RNA, oligonucleotide quantitation, purity check; Xenon lamp; Upgradable; w/SWIFT II Applications Software to form powerful system
- Robust, compact and reliable for general laboratory measurements
- Xenon lamp for longer lifetime by incorporating press-to-read technology and lower running costs
- Provides stored routines for DNA, RNA and oligonucleotide quantitation and purity check
- Combines basic measurement modes with enhanced software functionality and method storage
- User defined equations can be entered using the multi-wavelength mode and up to 18 methods can be saved
- Integral high resolution graphics display and easy-to-use software
- Includes routines for wavelength scanning, simple kinetics, reaction rate and standard curve
- Can be upgraded with SWIFT II Applications Software to form a powerful system
- Includes serial and parallel outputs as standard
Specifications Accuracy (Photometric) ±0.5% or ±0.003A to 3.000A at 54nm
Certifications/Compliance CE89/336/EEC (EMCdirective); CE73/23/EEC (LVdirective); EN-61010-1 (IEC1010-1)
Depth (English 5.5 in.
Depth (Metric) 14cm
Detector Type Two Silicon Photodiodes
Electrical Requirements 100 to 240V 50/60Hz
For Use With (Application) Nucleic acid measurements and enzyme kinetics
Height (English) 3.14 in.
Height (Metric) 8cm
Hertz 50/60Hz
Lamp Xenon
Scan Speed 3000nm/min.
Spectral Band width>3nm
Voltage 100 to 240V
Wavelength Accuracy ±1nm
Wavelength Range 190 to 900nm
Weight (English) 28 lb.
Weight (Metric) 13kg
Width (English) 8.26 in.
Width (Metric) 21cm
Product Type UV-visible
Click 'buy now' through our site to checkout! We accept major credit cards
Molecular Devices Spectramax Gemini XS including software loaded PC, Monitor, Keyboard and Mouse
Sold out
Contact for price
BLE1900217
Molecular Devices Spectramax 190 Microplate Reader with PC, Monitor, Keyboard and Mouse
Sold out
Contact to purchase
BLE1601101
Molecular Devices VersaMax Tunable Microplate Reader Including Computer and Software
Sold out
Contact to purchase
BLE140115
Promega GloMax Multi+ (Model E9032) Detection System
Sold out
BLE1800412
Injector System sold separately but pictured (Model E7081)
Luminescence Module: An advanced head-on photon-counting photomultiplier tube (PMT) provides unmatched signal-to-noise ratios, beating most standalone luminometers. The luminescence module can detect as little as 3 × 10–21 moles of luciferase, covering a dynamic range over 8 logs. A dual-masking system minimizes well-to-well cross-talk.
Fluorescence Module: Application-optimized Optical Kits simplify fluorescence operation while maximizing performance. Long-lived LED-based excitation lights minimize maintenance and variability in intensity. LED usage increases sensitivity by fully exciting the fluorophore and reducing nonspecific light leakage, a problem often found when using broad-spectrum light sources. The UV, Blue, Green, Red and AFC Optical Kits are included with the Fluorescence Detection Module.
- UV (Ex: 365nm, Em: 410–460nm)
- Blue (Ex: 490nm, Em: 510–570nm)
- Green (Ex: 525nm, Em: 580–640nm)
- Red (Ex: 625nm, Em: 660–720nm)
- AFC (Aminofluorocoumarin; Ex: 405nm, Em: 495–505nm)
Visible Absorbance Module: A 6-position filter wheel with 2 open positions ensures flexibility for a wide range of applications. An LED-based visible spectrum light source minimizes maintenance and variability. The Visible Absorbance Module has a reading range of 0–5.0 OD with an accuracy that deviates less than 2%. This module comes with filters for reading 450, 560, 600 and 750nm. A 490nm filter is available as an accessory.
UV-Visible Absorbance Module: This module comes with a 6-position filter wheel that includes filters for measuring 260, 280, 450, 560, 600 and 750nm. These filters accommodate UV DNA and protein quantitation in addition to ELISA and protein assays. Like the Visible Absorbance Module, you can customize the UV-Visible Absorbance Module by substituting a filter of your choice into either of two removable filter paddles.
Both single and dual injectors are available separately for the GloMax®-Multi+ Detection System.
The GloMax®-Multi+ Detection System may be configured with an optional heater allowing precise temperature control from 2°C above ambient temperature to 45°C +/– 0.75°C.
Injectors sold seperately
Click 'buy now' through our site to checkout! We accept credit card through Paypal.
BioTek Synergy 2 Multi-Mode Microplate Reader
Sold out
BLE1800354
Contact for price
Description
- Fluorescence intensity, time resolved fluorescence, fluorescence polarization, glow and flash luminescence, UV-Vis absorbance, FRET, TR-FRET, BRET, area scanning, adn spectral scanning
- Optical system includes a narrow band monochromator, optimized filter/dichroic mirror pairing and three broad spectrum light sources — SQ Xenon Flash, Tungsten Halogen and High Energy DPR Xenon Flash
- Modular design allows for easily upgrading elements
- Optimized throughput for screening assays in 6- to 1536-well plates (luminescence 6-384) and PCR plates
- Compatible with Take3 and Take3 Trio Micro-Volume plates — up to 16 or 48 2µL samples for low-volume DNA, RNA and protein quantification
- Temperature control from 4° above ambient to 50°C
- 11-120-515 includes two syringe pumps with dispensing volume of 5-1000µL in 1µL increments
Applications
- For in vitro diagnostic use (except in the European Union)
- Screening assays; Binding assays; Ion channel assays; Quantitative assays (DNA, protein); Kinetic assays; Gene expression assays (GFP, Luciferase); ELISA assays; Cell proliferation, Cytotoxicity
Compliance
CE and NRTL Safety Agency marked
Specifications
Product Type
With luminescence, fluorescence, absorbance
Resolution 0.001 O.D.
Measurement Speed 96 wells: 11 seconds; 384 wells: 22 seconds; 1536 wells: 42 seconds
Depth (English) 17.5 in.
Width (English)17 in.
Height (English) 14.5 in.
Weight (English) 60 lb.
Wavelength Range 200 to 999nm; 1nm increments
Dynamic Range 0 to 4.0 O.D.
Depth (Metric) 44.5cm
Width (Metric)
43.5cm
Height (Metric) 37.3cm
Weight (Metric)27kg
BioTek Synergy HT Reader with PC, Software, Keyboard & Mouse
Sold out
Contact for price
BLE1700003
Agilent 8453 G1103A Spectrophotometer with PC, Monitor, Keyboard and Mouse
Sold out
Contact to purchase
BLE1900156
BioTek Synergy H1 Microplate Reader
Sold out
Contact for price
BLE1800262
Supports:
Monochromator UV-Visible Absorbance Top and bottom Fluorescence and Luminescence