- Centrifuge Rotors
- >
- Beckman Coulter JS Series Rotors
- >
- Beckman Coulter JS-5.3 Centrifuge Rotor
Beckman Coulter JS-5.3 Centrifuge Rotor
BLE1900299
The highly versatile AllSpin rotoris ideally suited for Cellular Analysis, Genetic Analysis, and Protein Analysis providing you with a wide assortment of labware for your application requirements.
The 4-place design provides easy sample handling and ready access for time savings.
Productivity is further enhanced with fast acceleration and deceleration from powerfulAvanti SR* drive technology. And Beckman Coulter's Friction Reduction System delivers precise temperature control and energy saving results at up to 6,130 x g in both the Avanti J-26XP and Avanti J-E High Performance Centrifuges.
CELLULAR ANALYSIS: Up to 2L (4 x 500 mL) conical tube capability for efficient separation of cells, cell membranes, tissue homogenates, and blood cell components.
GENETIC ANALYSIS: Up to 24 (4 x 6 plates) 96-well plate capability for improved productivity in DNA isolation, purification, and post-reaction cleanup.
PROTEIN ANALYSIS: Up to 72 (4 x 18 place) 15 mL and 28 (4 x 7 place) 50 mL conical tube capability for fast preparation of protein/virus precipitates, and centrifugal filtration.
BIOSAFETY: Biocontainment from 5 mL tubes to 250 mL bottles and from PCR*** plates to deep well 96-well plates in a single rotor.
Spec
Maximum speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5300 rpm
Critical speed range* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500 to 1200 rpm
Density rating at maximum speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 g/mL
Relative Centrifugal Field
† at maximum speed Deep-well Plates 500-mL Conical Bottles
‡ At
rmax (194.8 mm) 6130 × g . . . . . . . . . . . . . . . . (218.4 mm) 6870 × g At
rav (179.6 mm) 5650 × g . . . . . . . . . . . . . . . . (155.6 mm) 4900 × g At
rmin (164.3 mm) 5170 × g . . . . . . . . . . . . . . . . . (92.7 mm) 2920 × g Conditions requiring speed reductions . . . . . . . . . . . . . . . . . . see RUN SPEEDS
k factor Deep-well plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1536
500-mL conical bottles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7728
Maximum allowable imbalance of opposing loads . . . . . . . . . . . . . . . . 10 grams
Maximum load per bucket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1040 grams
Number of buckets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Available labware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . see Tables 1 and 2
Approximate acceleration time to maximum speed
(fully loaded) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 min
Approximate deceleration time from maximum speed
(fully loaded) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
3/4 min Weight of fully loaded rotor . . . . . . . . . . . . . . . . . . . . . . . . . 14.03 kg (30.91 lb)
Rotor material. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . aluminum
Contact Us or click 'buy now' to checkout. We accept credit card through Paypal