Call:   617-209-2525  |  Email:  info@bostonlabco.com  |  
Boston Laboratory Equipment
  • Home
  • Categories
    • Analytical Instruments
    • Animal Care
    • Autoclaves
    • Balances
    • Bio Reactors
    • Cell Counters
    • Cell Separators
    • Centrifuges
    • Centrifuge Rotors
    • Chillers
    • Chromatography
    • Dissolution System
    • Evaporators, Spray Dryers, and Concentrators
    • Environmental Chamber
    • Gas Generators
    • Homogenizers & Ultrasonic Homogenizers
    • Hoods
    • Hot Plates & Stirrers
    • Incubators
    • Liquid Handling & Sample Preparation
    • Lyophilizers - Freeze Dry
    • Microscopes & Optical
    • Microwave Digesters & Synthesis
    • Moisture Analyzers
    • Mixers
    • Oven & Furnaces
    • Plate Reader / MicroPlate Reader
    • Plate Washers/ MicoPlate Washers
    • Plate Sealers/Plate Piercers
    • Pumps
    • Refrigerators & Freezers
    • Robotics & Stages
    • Rotovaps
    • Shakers
    • Speed Vac
    • Tablet Manufacturing Equipment
    • Thermal Cyclers
    • Titrators
    • Vacuum Pumps
    • Water Baths
    • Water Purification Units
    • Miscellaneous
  • Histology
  • Contact
  • Company Profile
  • Return Policy
  • Reviews
  • On Sale
  • Job Openings
  • Free Lab Equipment
  • Analytical Instruments
  • >
  • Shimadzu ON-LINE TOC-VCSH Total Organic Carbon Analyzer with ASI-V Auto Sampler

Shimadzu ON-LINE TOC-VCSH Total Organic Carbon Analyzer with ASI-V Auto Sampler

SKU: BLE130395
$3,900.00
$3,900.00
Unavailable
per item
Contact Us to Purchase
SN H51104535248cs
Offered Shimadzu Corporation TOC-VCSH Total Organic Carbon Analyzer with 40 mL vials x 68  ASI-V Auto Sampler Complete working System.
This system tested and is in excellent condition!
The functionality for continuous automatic measurement has bee added to the ability of the combustion catalytic oxidation/NDIR TOC-V Series to perform high-performance, high sensitivity measurement of organic substances.
The On-line TOC-VCSH can be used for Continuous automatic high-sensitivity monitoring of water samples such as pure water and tap water.
Combines Combustion Catalytic Oxidation at 680°C and NDIR Method
Combustion catalytic oxidation at 680°C oxidizes even persistent or insoluble organic compounds. This method accurately measures any type of organic substance not affected by interfering substances or the sample properties such as pH or conductivity.
Easy Maintenance
Combustion catalytic oxidation at 680°C eliminates the need for oxidizing reagents, saving the tasks of procuring and preparing reagents. No special draining operations are needed.
Support Software for Pharmaceutical Water Management Applications
The On-line TOC-VCSH incorporates software for automatically performing tests specified by Japanese Pharmacopoeia (resolution test) and USP (system suitability test). Combining the On-line TOC-VCSH with an OCT-1 (optional) enables fully automatic testing; setting the reagent is all that is required.
Wide Variety of TOC Measurement Methods
NPOC, IC, TC and TOC (TC-IC) measurements are possible with the ON-LINE TOC-VCSH. TN measurement is also possible by adding an optional product. TOC and TN can be measured simultaneously.
Main Applications
  • Management of pharmaceutical water
  • Management of ultrapure and recycled water for the semiconductor industry
  • Management of mains water
  • l Impurity contamination management for all types of water used at plants (cooling water, recycled water, and boiler water)
ON-LINE TOC-VCSH - Specifications:
  • Measured items NPOC (TOC by IC subtraction using acid sparging), TC, IC, TOC (TC-IC), TN (optional TNM-1 required)
  • Measurement method 680ºC combustion catalytic oxidation/NDIR method
                        720ºC combustion catalytic oxidation/ chemiluminescence method
                        (when TNM-1 is connected)
  • Measurement range TC: 0-500 ìg/L to 0-25,000 mg/L variable
                       IC: 0-500 ìg/L to 0-30,000 mg/L variable
  • Measurement cycle Approx. 5 to 999 minutes (for NPOC measurement)
  • Number of measurement channels 1 channel
  • Reproducibility CV 1.5% max.
  • Linearity ±2% F.S. max.
  • Zero stability ±2% F.S. max. per day
  • Span stability ±2% F.S. max. per day (ambient temperature fluctuations within 5ºC)
  • Calibration cycle Variable in the range 1 to 999 hours
  • Sample injection method Automatic injection using syringe pump/slider
  • Sample injection volume Variable in the range 10 to 2,000 uL
  • Sample dilution function Diluted in syringe; dilution factor: 2 to 50
  • IC pretreatment Automatic acidification and sparging
  • Carrier gas High-purity air or oxygen (1 ppm max. of CO, CO2, or HC)
             High-purity nitrogen (1 ppm max. of CO, CO2, or HC) (when using optional nitrogen gas carrier kit)
             Supply pressure: Approx. 600 kPa
             Flow rate: 150 mL/min (230 mL/min with sparging)
  • Measurement value output Analog output: Select from 4 to 20mA, 0 to 16mA (insulation, load resistance: 750Ù max.), and 0 to 1VDC RS-232C: Baud rate; 9,600 bps, Data length; 8 bits, Parity; none, Stop bits; 1
  • Alarm output Measurement value upper limit and upper upper limit alarms, system error alarm: No-voltage contact output (maximum: 5VA, 0.1A, 50V)
  • Control input Remote stopping and starting of sample measurement and calibration
  • Sample conditions Flow rate: Approx. 0.1 to 1 L/min
  • Sample volume: 5 to 7 mL per measurement
  • Temperature: 0 to 90ºC
  • Ambient temperature 5 to 35ºC
  • Power supply AC 100 - 127V ±10% MAX 800VA 50/60 Hz
                AC 200 - 240V ±10% MAX 1200VA 50/60 Hz
  • Dimensions Approx. 440 (W) x 560 (D) x 460 (H) mm (excluding protrusions)
  • Weight Approx. 40 kg
ASI-V Auto Sampler Features: 
  •  have a well-sealed septum that can be easily replaced with the screw cap.
  • The sampling needle is optimized for sample extraction from highly sealed vials and for sparging.
  • Changing analysis conditions or adding sample vials during analysis is simple. System operation and carrier gas flow can be automatically stopped on completion of measurements.
  • Creating multiple calibration curves and selecting the optimal curve for samples with significantly differing concentrations allows these samples to be analyzed in a single run.
  • Rinsing both external and internal surfaces of the sampling needle prevents carryover between samples.
  • Vial types: 40mL
  • Number of vials: 40mL X 68
  • Vial Septum With dedicated septum
  • Sample sparging OK (If the external sparging kit is used)
  • Dimensions Approx. (W)370 x (D)540 x (H)490mm
  • Weight Approx. 14 kg