Waters e2695 Alliance HPLC Separations System
SKU:
BLE1700309
$0.00
Unavailable
per item
Contact for price
BLE1700309
Sold out
Waters e2695 Separation Module
Waters 2998 Photodiode Arrady Detector
3 Pc. Separations System include:
(1) Alliance e2695 Separations Module,
(1) Column Heater G14SMC 659G
(1) Model 2998 Photodiode Array Detector
Includes:
Testing:
This unit was tested extensively using the materials we had on hand. All the solvent pumps were tested with DI water and (A, B, C, D). The sample manager was tested by taking samples of sugar water from 2mL vials in various placements on the carousels. After a dry prime (initiated from the machine screen) and equilibration these samples were then run through a column with 3um particles and then the PDA. The results from the tests using sugar water were very consistent with several peaks in the UV range across multiple samples (see pictures). All proportioning valves, syringe, injectors, etc. are tested.
Waters 2998 Photodiode Arrady Detector
3 Pc. Separations System include:
(1) Alliance e2695 Separations Module,
(1) Column Heater G14SMC 659G
(1) Model 2998 Photodiode Array Detector
Includes:
- Computer with Empower 3 is included
- Computer has been tested with the unit
- All the pieces connect to the computer via ethernet switch
- Sample manager has 5 carousels with 24 wells for 2mL vials for a total of 120 vials.
- Temperature range is 4 to 40 °C
- 0.1 to 100 uL typical injection volume, but up to 2mL with addition of 2mL sample loop.
- Solvent manager for 4 solvents
- All solvents are degassed
- Maximum operating pressure is 5000 PSI
- 0.05 to 5 mL/min flow rate typically, but absolute limits are 0 to 10 mL/min
- Column heater/cooler has a temperature range between 4 and 65 °C
- Columns up to 30mm Length and 7.8mm ID can fit in this unit
- Up to 4 columns can fit in this heater/cooler
- Columns can be plumbed in series
- Column selection valve can select between 6 different columns
- PDA detector 2998
- Brand new lamp!
- Can record single wavelength and full spectrum information simultaneously
- The PDA has a TaperSlit flow cell
Testing:
This unit was tested extensively using the materials we had on hand. All the solvent pumps were tested with DI water and (A, B, C, D). The sample manager was tested by taking samples of sugar water from 2mL vials in various placements on the carousels. After a dry prime (initiated from the machine screen) and equilibration these samples were then run through a column with 3um particles and then the PDA. The results from the tests using sugar water were very consistent with several peaks in the UV range across multiple samples (see pictures). All proportioning valves, syringe, injectors, etc. are tested.