- Analytical Instruments
- >
- Nova Biomedical Bioprofile CDV Cell Density and Viability Analyzer
Nova Biomedical Bioprofile CDV Cell Density and Viability Analyzer
SKU:
BLE1800173
$0.00
Unavailable
per item
Contact for price
BLE1800173
1 available
BioProfile CDV incorporates advanced, state-of-the-art technology for rapid, accurate measurement of cell density and cell viability in cell cultures. Based on the widely recognized and accepted trypan blue exclusion method, BioProfile CDV combines advanced technology in robotics, optics and computer algorithms in a highly automated analyzer:
Walk-Away Sample Analysis
A fully-automated, 12-position sample tray allows walk-away sample analyses. Samples can be continuously added to the tray, allowing continuous workflow.
Easy-to-Use, Intuitive Interface
BioProfile CDV’s touchscreen interface includes time-saving features like an autocomplete function for faster same ID, batch ID, vessel ID, and cell type entry. Operation is as simple as entering sample information, loading sample cups, and touching" Analyze". Results are displayed for each sample as soon as testing is complete
High-Resolution Vision System
A high resolution vision system provides precise auto-focusing on a mono-layer of cells within the counting chamber and captures high-quality cell images. Images from up to 40 optical fields are captured in seconds.
Fast Cell Counts, Less Than 3 Minutes
BioProfile CDV automation, high-speed image capture and image processing combine to provide fast cell counts and high throughput. A comprehensive cell count is available in less than 3 minutes, with throughput up to 20 samples per hour. Test results include:
Total cell density
Viable cell density
Percent viability
Live cell diameter
Live cell standard deviation/histogram
Accurate, Reproducible Cell Counts
Advanced algorithms rapidly process images from up to 40 optical fields, allowing thousands of cells to be counted for more accurate, reproducible cell counts.
Low Cost of Operation
BioProfile CDV reduces operating cost by consuming minimal reagent volumes. Easy-to-use reagent cartridges analyze over 300 samples per cartridge and can be replaced in minutes.
Specifications
Sample Analysis Time:
2.5 minutes (Gases only – PO2 + PCO2) 4.0 minutes
(Chemistry/Gas & Osmolality)6.25 minutes
(All 15 tests)
Operating Temperature Range: 15-30°C (59-86°F)
Operating Relative Humidity Range: 20-85%
Sample Size: 1 mL (for all modules)
Sampling Options: Individual via syringe/cup
Automated batch using 20-position sampling tray
On-line, automated from up to ten bioreactors
Electrical Requirements: 90-264 VAC, 50 to 60 Hz (Universal Power Supply)
System Size: Height: 20 in (50 cm) Width: 26 in (66 cm) Depth: 20 in (50 cm)
System Weight: Analyzer: 94 lbs (42.6 kg) without reagents
Host Computer Monitor/CPU: 41.5 lbs (18.8 kg)
Safety Certifications: TUV: IEC 61010-1:2001
Quality Systems Certifications: TUV: ISO9001:2000 FDA Registered, OPC Compliant, PAT Compatible, 21 CFR Part 11 Compliant
Walk-Away Sample Analysis
A fully-automated, 12-position sample tray allows walk-away sample analyses. Samples can be continuously added to the tray, allowing continuous workflow.
Easy-to-Use, Intuitive Interface
BioProfile CDV’s touchscreen interface includes time-saving features like an autocomplete function for faster same ID, batch ID, vessel ID, and cell type entry. Operation is as simple as entering sample information, loading sample cups, and touching" Analyze". Results are displayed for each sample as soon as testing is complete
High-Resolution Vision System
A high resolution vision system provides precise auto-focusing on a mono-layer of cells within the counting chamber and captures high-quality cell images. Images from up to 40 optical fields are captured in seconds.
Fast Cell Counts, Less Than 3 Minutes
BioProfile CDV automation, high-speed image capture and image processing combine to provide fast cell counts and high throughput. A comprehensive cell count is available in less than 3 minutes, with throughput up to 20 samples per hour. Test results include:
Total cell density
Viable cell density
Percent viability
Live cell diameter
Live cell standard deviation/histogram
Accurate, Reproducible Cell Counts
Advanced algorithms rapidly process images from up to 40 optical fields, allowing thousands of cells to be counted for more accurate, reproducible cell counts.
Low Cost of Operation
BioProfile CDV reduces operating cost by consuming minimal reagent volumes. Easy-to-use reagent cartridges analyze over 300 samples per cartridge and can be replaced in minutes.
Specifications
Sample Analysis Time:
2.5 minutes (Gases only – PO2 + PCO2) 4.0 minutes
(Chemistry/Gas & Osmolality)6.25 minutes
(All 15 tests)
Operating Temperature Range: 15-30°C (59-86°F)
Operating Relative Humidity Range: 20-85%
Sample Size: 1 mL (for all modules)
Sampling Options: Individual via syringe/cup
Automated batch using 20-position sampling tray
On-line, automated from up to ten bioreactors
Electrical Requirements: 90-264 VAC, 50 to 60 Hz (Universal Power Supply)
System Size: Height: 20 in (50 cm) Width: 26 in (66 cm) Depth: 20 in (50 cm)
System Weight: Analyzer: 94 lbs (42.6 kg) without reagents
Host Computer Monitor/CPU: 41.5 lbs (18.8 kg)
Safety Certifications: TUV: IEC 61010-1:2001
Quality Systems Certifications: TUV: ISO9001:2000 FDA Registered, OPC Compliant, PAT Compatible, 21 CFR Part 11 Compliant