Titrators
Mettler Toledo T70 Tirator with Rondo Tower, Optional Dosing Unit and Burettes
Contact for Pricing
BLE1800365
Optional Dosing Unit - $2,200.00
Optional Burette - $500.00 each
Mettler Toledo C20 Coulometric KF Titrator
Contact to Purchase
BLE1700225
SN B228119038
Excellent Condition. Fully tested and ready to ship. 30 Day Money Back Guarantee!!!
One Click solvent exchanges ease the task of emptying and filling the vessel—and all other daily tasks can be simplified to One Click Shortcuts on the Home Screen. True Plug-and-Play technology adds automatic recognition of burets on the V20, further enhancing security.
- Simple and fast operation
- Safe handling of chemicals
- Easy-to-use touchscreen interface
- User-specific Home Screen featuring intuitive shortcuts for routine tasks
- Coulometric generation cell; choose Model C20D with diaphragm or Model C20X without diaphragm
Specifications
- mV Range-2000 to 2000 mV
- Resolution 0.1 mV
- Temperature Range (English) Ambient 41° to 104°F
- Temperature Range (Metric) Ambient 5° to 40°C
Metrohm 774 Oven Sample Processor Complete System
BLE140165
Metrohm 774 Oven Sample Processor + 831 KF Coulometer + 846 Dosing Interface
This System Includes:
1) 774 Oven Sample Processor
2) 774 SC Controller
3) 728 Stirrer
4) 800 Dosino 50mL
5) 831 KF Coulometer
6) 846 Dosing Interface
7) Edgeport USB Converter
8) Titration Vessel
In principle the 774 Oven Sample Processor can be used with all samples that release their water when heat is applied. However, the KF oven method is essential whenever direct volumetric or coulometric Karl Fischer titration is impossible because the sample contains interfering components or, due to its consistency, is difficult to place in the titration vessel.
The combination of the 774 Oven Sample Processor with coulometric Karl Fischer titration (756 or 831 KF Coulometer) is ideal for samples with a low water content. Foodstuffs, pharmaceutical products, plastics or mineral oil products can be analyzed fully automatically and extremely accurately. On the other hand, a volumetric Karl Fischer titration using a KF Titrino is to be
preferred for samples with a very high water content (>50%).
In accordance with the gas extraction principle the water is driven out of the heated sample by a stream of dry carrier gas and transferred to the titration vessel, where the water is determined by KF titration.
For temperature-sensitive samples, e.g. foodstuffs, the water can be released gently at lower temperatures by simultaneous extraction with methanol. In this way it is possible to prevent any water being released by decomposition.
This Application Bulletin uses examples from the food, pharmaceutical, plastics and petrochemical industries to describe automatic Karl Fischer water determination using the 774 Oven Sample Processor and a KF Coulometer.
Information concerning the combination of the Oven Sample Processor with a volumetric KF titrator is given in brackets.
The Metrohm 774 Oven Sample Processor Overview
1.1 Application range
The Metrohm 774 Oven Sample Processor is a very versatile instrument. It has been specially designed for laboratory use and can be used for a wide range of applications. It provides an essential service when large numbers of samples have to be processed in which the samples require to be heated and/or whenever it is necessary to remove moisture or organic sol-vents from solids or liquids by the application of heat.
The construction of the 774 Oven Sample Processor has been principally based on the determination of moisture by the oven method. The sample heated in the oven block releases its moisture as water vapor which is transferred to a measuring cell in a stream of gas. The moisture determina- tion in the cell can be carried out either coulometrically or volumetrically ac-cording to Karl Fischer.
This method is becoming increasingly popular wherever moisture determi-nations have to be carried out in matrices which interfere with the moisture determination process or which release their moisture only with great diffi-culty.
831 KF Coulometer incl. diaphragmless generatorelectrode
Economical KF Coulometer with diaphragmless titration cell for water determi-nation right down to trace levels. The KF Coulometer has established itself forthe determination of very small amounts of water. Thanks to its reliability, back-lit graphical display, multilingual dialog and easy operation, the 756 KF Coulom-eter has become standard equipment in many laboratories. The clear displayprovides information about the relevant titration parameters and gives anunmistakable presentation of the course of titration in the form of a curveshowing µg water against time. Recommended measuring range: 10 µg...200mg absolute water.
Metrohm 730 Sample Changer Titration System
Price: $4,800.00
BLE1700204
System in Excellent Condition, tested and ready to ship!
Includes:
- 730 Sample Changer
- 759 Swing Head
- Sample Rack
- 802 Stirrer
- SC Controller
- 716 DMS Titrino
- 716 DMS Titrino Keyboard
- BK730 Remote Box
Metrohm 860 Thermoprep System with 756 KF Coulometer, 728 Stirrer and PC with Tiamo 2.5 Full
Contact for price
BLE1800482
Metrohm 874 Oven Sample Processor and 756 KF Coulometer Titration System
Contact for price
BLE1800376
Metrohm 832 Thermoprep System w/ 756 KF Coulometer + Keyboard, and 728 Stirrer
Free shipping available
BLE1601088
Includes:
832 Thermoprep
756 KF Coulometer
756 KF Coulometer Keyboard
728 Stirrer
Click 'buy now' through our site to checkout with free shipping! We accept major credit cards
Metrohm 841 Titrando w/ 804 Ti Stand
Sold out
Free shipping available
BLE1800355
Includes:
841 Titrando
804 Ti Stand
Click 'buy now' through our site to checkout with free shipping! We accept major credit cards
Metrohm 841 Titrando w/ 803 Ti Stand, 800 Dosino, Glassware
Sold out
Free shipping available
BLE1800426
Includes:
841 Titrando
803 Ti Stand
800 Dosino (2mL)
Glassware Seen In Photos
Click 'buy now' through our site to checkout with free shipping! We accept major credit cards
Metrohm 901 Titrando w/ 803 Ti Stand, 800 Dosino, Glassware, Electrode
Sold out
Free shipping available
BLE1800477
Includes:
901 Titrando
803 Ti Stand
800 Dosino (2mL)
Double Pt-Wire Electrode for Volumetry 6.0338.100
Glassware Seen In Photos
Click 'buy now' through our site to checkout with free shipping! We accept major credit cards
Mettler Toledo V30 Volumetric KF Titrator with P25 Printer
Sold out
BLE1800109
Contact to purchase
Mettler Toledo Rondo Tower Titrator
Sold out
Price: $3,800.00
Main advantages:
- Sample preparation separated from the titration stand
- Separation of titrations on a single sample
- Automatic combination of titrations on two samples
- Easy switch between two titration stands (e.g. for aqueous / non-aqueous titrations)
SN 5130377687
Metrohm 874 Sample Oven and 831 KF Coulometer System w/ Tiamo 2.5 Full On Win 10 PC
Sold out
Contact for price
BLE1900001
Sold items -- Please inquire about others in stock; We get daily shipments

water determination
SOLD